• Nanion Technologies: イオンチャネル研究のスマートツール

    Nanion Technologies: イオンチャネル研究のスマートツール

  • CardioExcyte 96 SOL: 心筋の光ペーシング

    CardioExcyte 96 SOL: 心筋の光ペーシング

  • SURFE²R 96SE: ラベルフリーのトランスポーターHTS

    SURFE²R 96SE: ラベルフリーのトランスポーターHTS

  • 脂質二分子膜実験: Orbitシリーズ

    脂質二分子膜実験: Orbitシリーズ

Our Product Portfolio

SyncroPatch 384i

SyncroPatch 384i

Patchliner

Patchliner

Port-a-Patch

Port-a-Patch

Port-a-Patch mini

Port-a-Patch mini

CardioExcyte 96

CardioExcyte 96

FLEXcyte 96

FLEXcyte 96

SURFE²R 96SE

SURFE²R 96SE

SURFE²R N1

SURFE²R N1

Orbit 16

Orbit 16

Orbit Mini

Orbit Mini

Vesicle Prep Pro

Vesicle Prep Pro

NaV1.5 - "Pharmacology of hNaV1.5 recorded on Nanion's Patchliner"

icon pl   Patchliner application note:   logo pdf   (0.3 MB)
Cells were kindly provided by Millipore.

Summary:

Voltage gated sodium channels (NaV) are important elements of action potential initiation and propagation in excitable cells. The channels are activated upon a depolarization of the membrane. Their activation leads to further depolarization of the membrane which constitutes the upstroke of the action potential. NaV currents generally activate very fast (within 1-2 ms) upon depolarization of the membrane. Hence, a good and stable access resistance is critical for high quality pharmacological patch clamp recordings. Also, for automated patch clamp devices, it is not a given that applied compound concentrations are accurately delivered to the cell. This is a pre-requisite for accurately reproducible dose-response curves. Here we present data collected on the 8-channel Patchliner. Tetrodotoxin and lidocaine dose‑response curves on hNaV1.5 expressed in HEK293 cells are shown. Lidocaine has been shown to block hNaV1.5 in its inactivated state (Bean et al. 1983) which means that the IC50 of lidocaine becomes dependent on the holding potential. This dependence was investigated. We also demonstrate the stability and reproducibility of the data collected with the Patchliner. Using two sequential dose responses of hNaV1.5 to TTX we demonstrate that the compound concentrations are accurately delivered to the cells and that recordings are stable with robust access resistance.

Back

Nanion コーポレートブログ

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.