• Nanion Technologies: イオンチャネル研究のスマートツール

    Nanion Technologies: イオンチャネル研究のスマートツール

  • CardioExcyte 96 SOL: 心筋の光ペーシング

    CardioExcyte 96 SOL: 心筋の光ペーシング

  • SURFE²R 96SE: ラベルフリーのトランスポーターHTS

    SURFE²R 96SE: ラベルフリーのトランスポーターHTS

  • 脂質二分子膜実験: Orbitシリーズ

    脂質二分子膜実験: Orbitシリーズ

Our Product Portfolio

SyncroPatch 384/768PE

SyncroPatch 384/768PE

Patchliner

Patchliner

Port-a-Patch

Port-a-Patch

CardioExcyte 96

CardioExcyte 96

SURFE²R 96SE

SURFE²R 96SE

SURFE²R N1

SURFE²R N1

Orbit 16

Orbit 16

Orbit Mini

Orbit Mini

Vesicle Prep Pro

Vesicle Prep Pro

2018 - Combining electrophysiology and contractility recordings for more complete assessment of hiPSC-CMs

icon sp96   SyncroPatch 384PE,   icon pl   Patchliner and   Icon CardioExcyte 96 simpel RGB   CardioExcyte 96 poster, Europhysiology Meeting 2018  logo pdf   (1.4 MB)

Abstract:

Human induced pluripotent stem cells (hiPSCs) are becoming increasingly important for cardiac safety testing due to their recapitulation of native behaviour, relative abundance and ease-of-use. We combine automated patch clamp (APC), impedance and extracellular field potential (EFP) measurements to study hiPSC-derived cardiomyocytes (hiPSC-CMs) from different sources. In line with the comprehensive in vitro proarrhythmia assay (CiPA) initiative, cardiac ion channels expressed in heterologous expression systems have been recorded on APC devices at room temperature and at physiological temperature and the effect of different pro-arrhythmic compounds on ion channels was investigated. In addition hiPSC-CMs were used on APC platforms recording from 8 or 384 wells simultaneously. Voltage-gated Na+ (NaV), Ca2+ (CaV) and K+ (KV) currents were recorded in voltage-clamp and action potentials recorded in current clamp mode. Using the dynamic clamp technique coupled with an APC device, electrically modelled IK1 was injected into the cell under current clamp conditions and this resulted in a more hyperpolarized and stable resting membrane potential. Within the myocyte phase II study of the CiPA initiative, a device combining impedance-based contractility and extracellular field potential (EFP) recordings was used to investigate the effects of different compounds deemed low, intermediate and high risk by the FDA. Different hiPSC-CMs were used in a large cross-site evaluation and the results are summarised here.

Back

Nanion コーポレートブログ

Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.
More information Ok