2015 - Automated Formation of Lipid Membrane Microarrays for Ionic Single-Molecule Sensing with Protein Nanopores

Icon Orbit  Orbit 16 publication in Small (2015)

Authors: 
Del Rio Martinez J.M., Zaitseva E., Petersen S., Baaken G., Behrends J.C.

Journal: 
Small (2015) 11(1):119-125


Abstract: 

Efficient use of membrane protein nanopores in ionic single-molecule sensing requires technology for the reliable formation of suspended molecular membranes densely arrayed in formats that allow high-resolution electrical recording. Here, automated formation of bimolecular lipid layers is shown using a simple process where a poly(tetrafluoroethylene)-coated magnetic bar is remotely actuated to perform a turning motion, thereby spreading phospholipid in organic solvent on a nonpolar surface containing a <1 mm2 4 × 4 array of apertures with embedded microelectrodes (microelectrode cavity array). Parallel and high-resolution single-molecule detection by single nanopores is demonstrated on the resulting bilayer arrays, which are shown to form by a classical but very rapid self-assembly process. The technique provides a robust and scalable solution for the problem of reliable, automated formation of multiple independent lipid bilayers in a dense microarray format, while preserving the favorable electrical properties of the microelectrode cavity array.


Download here

Back

Nanion コーポレートブログ

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.