• SyncroPatch 384

    Next level versatility and flexibility
  • SyncroPatch 384

    True HTS and GigaOhm seals
  • SyncroPatch 384

    Your multi purpose instrument
  • SyncroPatch 384

    Powerful analysis software
  • SyncroPatch 384

    Assay flexibility via high tech
  • SyncroPatch 384

    Heating and cooling of solutions, cells and patch clamp sites

2020 - Accounting for variability in ion current recordings using a mathematical model of artefacts in voltage-clamp experiments

icon sp96   SyncroPatch 384PE (a predecessor model of the SyncroPatch 384i) publication in Philosophical Transactions of the Royal Society A (2020)

Authors:
Lei, C.L., Clerx, M., Whittaker, D.G., Gavaghan, D.J., de Boer, T.P., Mirams, G.R.

Journal:
Philosophical Transactions of the Royal Society A (2020) 378: 20190348.doi: 10.1098/rsta.2019.0348


Abstract:

Mathematical models of ion channels, which constitute indispensable components of action potential models, are commonly constructed by fitting to whole-cell patch-clamp data. In a previous study, we fitted cell-specific models to hERG1a (Kv11.1) recordings simultaneously measured using an automated high-throughput system, and studied cell-cell variability by inspecting the resulting model parameters. However, the origin of the observed variability was not identified. Here, we study the source of variability by constructing a model that describes not just ion current dynamics, but the entire voltage-clamp experiment. The experimental artefact components of the model include: series resistance, membrane and pipette capacitance, voltage offsets, imperfect compensations made by the amplifier for these phenomena, and leak current. In this model, variability in the observations can be explained by either cell properties, measurement artefacts, or both. Remarkably, by assuming that variability arises exclusively from measurement artefacts, it is possible to explain a larger amount of the observed variability than when assuming cell-specific ion current kinetics. This assumption also leads to a smaller number of model parameters. This result suggests that most of the observed variability in patch-clamp data measured under the same conditions is caused by experimental artefacts, and hence can be compensated for in post-processing by using our model for the patch-clamp experiment. This study has implications for the question of the extent to which cell-cell variability in ion channel kinetics exists, and opens up routes for better correction of artefacts in patch-clamp data.


Download here

Back

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.